Eye & Contact Lens Science & Clinical Practice · 2014 · 48 citations · 15 references
Health ProfessionsOphthalmologySurgeryClinical Vision ScienceOcular DiseaseOphthalmic SurgeryCataract ManagementContact Lens Clinical PracticeContact Lens InterventionsRigid Gas Permeable LensesRigid Gas-permeable Contact LensesVisual ImpairmentAcuity In Corneal DiseaseForeign Body Sensation ManagementRgp Lens FittingRigid Gas Permeable Lens OpticsRigid Gas Permeable Lens Prescribing
OBJECTIVE: To compare the best-corrected visual acuity (BCVA), vision-related quality of life (VRQoL), comfort, foreign body sensation in the eye, tolerance, and handling of ClearKone-Synergeyes hybrid contact lenses and rigid gas-permeable (RGP) lenses in patients with keratoconus. METHODS: This comparative case series was conducted between 2011 and 2012 on 40 keratoconic patients (20 in each group). The BCVA of each patient was evaluated on the same day when the lens was prescribed. The National Eye Institute Visual Functioning Questionnaire (NEI-VFQ 25) questionnaire was assessed in addition to other subjective criteria 2 months after the lens prescription. RESULTS: The BCVA did not show a significant difference between the two lenses. Of the subjective criteria, the scores of the domains of general vision (P=0.008), ocular pain (P<0.001), distance activity (P=0.008), mental health (P<0.001), role difficulty (P<0.001), dependency (P=0.016), driving (P=0.067), total score of the NEI-VFQ 25 questionnaire (P<0.001), and comfort (P<0.001) were significantly higher in the ClearKone-Synergeyes group when compared with the RGP group. Foreign body sensation was statistically higher with RGP lens versus the ClearKone-Synergeyes lens (P=0.013). Regarding tolerance, the preference of the ClearKone-Synergeyes lens over the RGP lens was borderline (P=0.085). CONCLUSION: Although the BCVA did not differ significantly between the two lenses and both corrected vision to the same extent, satisfaction and VRQoL was better in keratoconic patients who used the ClearKone-Synergeyes lens in comparison with the RGP lens.
15
Quality of life in keratoconus
Steven Kymes, Jeffrey J. Walline, Karla Zadnik et al. · American Journal of Ophthalmology · 2004 · 253 citations
Changes in the Quality-of-Life of People with Keratoconus
Steven Kymes, Jeffrey J. Walline, Karla Zadnik et al. · American Journal of Ophthalmology · 2008 · 180 citations · Full text
Modern Scleral Lenses Part II: Patient Satisfaction
Esther-Simone Visser, Rients Visser, Henk J.J. van Lier et al. · Eye & Contact Lens Science & Clinical Practice · 2007 · 105 citations
Medicine, Ophthalmology, Surgery +15