Study on High SPL Sound of Gas Heater Composed of Two Parallel Located Ducts with Tube Bundles (1st Report, Understanding of Phenomenon).

Kunihiko ISHIHARA

TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B · 2004 · 13 citations · 5 references

DOIFull text

Open access

Concepts

Abstract

This paper describes a High SPL sound generated from banks of gas heater tubes in two ducts with an internal flow which are located parallel to each other and used in a boiler. In this experiment, two banks have either of two kinds of tubes with diameter of 6 mm or 3 mm. The sound pressure and the flow velocity are measured in order to clarify the generation mechanism of the High SPL sound. First, the relation between the velocity and the sound pressure level (SPL) is examined. Second, the acoustic modes of the ducts are calculated by FEM. Finally, the effect of various perforated baffle plates on the SPL is studied. As a result, it was found that the beat phenomenon occurs in the gas heater with two banks because of the existence of two different acoustic modes which frequencies are very close to each other and the perforated baffle plates have a damping effect and the damping ability increases with the perforated ratio being smaller.

References

5