Journal of Chromatographic Science · 1978 · 18 citations · 0 references
PharmacyPharmaceutical AnalysisPharmacologyAnalytical ChemistryChromatographic AnalysisMass Spectrometric AnalysisAnalytical ChromatographyChromatographyLiquid ChromatographyHigh-performance Liquid ChromatographyHigh-performance Liquid Chromatography Method DevelopmentSilica Gel Treatment
A sensitive and specific method for the determination of quinidine in plasma is described. Quinidine is extracted with chloroform, the extract is evaporated and reconstituted with methanol and the methanol extract is analyzed by high-performance liquid chromatography using a silica gel column. The recovery of quinidine from plasma varied between 93.0 to 100%. Quinidine levels as low as 12 ng/ml can be detected by this method.