Comparative study of recessed and non-recessed swirl coaxial injectors

Masaki Sasaki, Hiroshi Sakamoto, M. Takahashi, Takeo Tomita, Hiroshi Tamura, Masaki Sasaki, Hiroshi Sakamoto, M. Takahashi, Takeo Tomita, Hiroshi Tamura

33rd Joint Propulsion Conference and Exhibit · 1997 · 33 citations · 1 references

Concepts

Abstract

The combustion characteristics of swirl-coaxial injectors with LOX/hydrogen were experimentally evaluated. Cold flow tests with water/nitrogen gas showed the known self-pulsating flow with swirl-coaxial injectors with recessed LOX post Combustion tests with single element combustors were conducted at chamber pressures of 2.6 MPa and 3.5 MPa, thrusts of 850 N and 500 N, and an oxidant to fuel ratio of 4.0 to 8.0. Combustion performance, chamber pressure distribution, and heat load on the chamber wall for each injector were measured and analyzed. The results indicated that the combustion performance was mainly limited by the vaporization efficiency in the shear-coaxial injector and by the mixing efficiency in the swirl-coaxial injectors. A significant increase of heat load on the chamber wall was observed with recessed swirl-coaxial injectors, and in some cases, the occurrence of unstable combustion was also observed.

References

1