A radial-flow apparatus for determining the thermal conductivity of loose-fill insulations to high temperatures

D R Flynn

Journal of Research of the National Bureau of Standards Section C Engineering and Instrumentation · 1963 · 14 citations · 2 references

DOIFull text

Open access

Concepts

Abstract

I A desc rip t ion is give n of an apparatus used for de ter minin g t he thermal conductivities of loose-fill granular ma terials in t he temperature ran ge 100 to 1,100 C . The method used in makin g these deter minations was t hat of radial heat flow thro ugh a hollo w cylinder of s pecimen m ate rial contain ed between a central-ceramic core and an outer ceramic shell. The heat flo w throu gh the specimen ,,-as determin ed b y m easurem ent of t he power inpu t to a heater in t he ce nt ral cerami c core. The radial tcmperature drop through t he specim en was inferre d fr om temperat ures measured in the core a nd in t he shell, t hu s avoid in g entirely t he problem s of mea surin g a te mperatu re differen ce wi t hin t he spec im e n ma ter ial. Experimental res ults wit ll an estim ated uncertain ty of 3 percen t or less are presen ted for diatomaceous eart h havin g a dens ity of 0 . 15 g/cm 3 , and for a luminum oxide powders having dens ities of 0.40 and 0.44 g/cm3 A discllssion of the lest m ethod is g iven, with atte ntion to possible sources of error. J ' Equation ( To convert E)-Saelen's eq (38) to the form presented above, it is helpful to make use of the identity arccosb x-arccosh y=arccosh (x y-;f(x2-1)(y2-1)).

References

2