Therapeutic Drug Monitoring · 2014 · 15 citations · 14 references
PharmacyPharmacokineticsPharmacologyAnalytical ChemistryBiopharmaceuticsMass Spectrometric AnalysisBioanalytical Method ValidationChromatographic Analysis Of PharmaceuticalsChromatographyImmunosuppressant MonitoringLiquid ChromatographyMass SpectrometryAnalytical Liquid ChromatographyCyclosporine PharmacokineticsHigh-performance Liquid Chromatography-mass SpectrometryLiquid Chromatography-mass SpectrometryLiquid Chromatography-mass Spectrometry AnalysisLiquid Chromatography-mass Spectrometry Method DevelopmentMultiple Reaction MonitoringTandem Mass Spectrometry
Immunosuppressant drugs (ISDs) are commonly prescribed to solid organ transplant patients. Their narrow therapeutic index and potential for toxicity necessitates careful monitoring of blood concentrations. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods are increasingly used for ISD measurement. However, there remain many challenges with this methodology, particularly regarding interassay variability. The Thermo Scientific Prelude is an online extraction/liquid chromatography platform that uses turbulent flow technology coupled with MS/MS. A multicenter evaluation of the Prelude for the measurement of cyclosporine A, tacrolimus, and sirolimus is described. ISDs were measured at each site using standardized protocols. Sample preparation liquid chromatography-MS/MS was performed using the Prelude coupled to a TSQ Vantage. Chromatography was achieved with a Cyclone-P TurboFlow/Accucore C8 column combination using a multisolvent loading and eluting pump system. Mass spectrometry acquisitions were performed in selective reaction monitoring mode and data processed using TraceFinder (version 3.1). Multisite mean imprecision for cyclosporine A ranged from 8.8% (54 mcg/L) to 9.8% (450 mcg/L); for tacrolimus, 4.7% (15.5 mcg/L) to 12.6% (2.5 mcg/L); for sirolimus, 7.4% (19.9 mcg/L) to 16.5% (2.6 mcg/L). Approximately 110 specimens were used for method comparison. For cyclosporine A, mean bias against the multisite mean ranged from -18% to 1%; for tacrolimus, values ranged from -7% to 4%; for sirolimus, values ranged from -4% to 2%. Comparisons of multisite mean Prelude results with routine ISD method results was also performed for cyclosporine A (slope = 0.7878, intercept = 24.16, r = 0.98), tacrolimus (slope = 0.9391, intercept = 0.1017, r = 98), and sirolimus (slope = 0.9618, intercept = 0.1483, r = 0.97). The Prelude ISD method offers acceptable and comparable multisite performance. This study has also highlighted the importance of adopting standardized protocols and LC-MS/MS methods for better comparability between ISD assays.
14