Laboratory Investigation on the Static Response of Repaired Sewers

T. C. Michael Law, Ian D. Moore

2002 · 10 citations · 1 references

Concepts

Abstract

This paper examines and characterizes the structural response of intimately fitted repaired sewers due to disturbance in the vicinity (e.g. vehicle loads). This soil-host pipe-liner interaction is investigated by full scale laboratory testing. The test geometry and measurement scheme are described. Mechanisms affecting local bending at host pipe fractures are identified. A comparison is made between response for the HDPE liner within a fractured non-reinforced concrete pipe, and that same HDPE liner buried alone in soil. Under earth disturbance, the fractures in the host pipe expanded at the inner surface at the crown and invert, and at the outer surface at the springlines. This expansion of fractures caused contacts between the inner edges of the host pipe and the liner at the crown and invert. The liner response was dominated by the local bending that resulted.