Journal of Thermophysics and Heat Transfer · 2002 · 78 citations · 9 references
Natural SciencesPhysicsHeat TransferPlasma PhysicsThermal AnalysisCalorimetryHigh-temperature PlasmasPlasma DiagnosticsPlasma HeatingPlasma SimulationPlasma SourcesHeat Content MeasurementsInductively Coupled Plasma SourcesPlasma Processes
Thedesignoftheplasmawindtunnel (PWK3),itsinductivelyheatedplasmagenerator (IPG3),andexperimental results using O 2 and CO2 as operational gases are described. Various operational conditions (mass e ow rate, frequency) were applied. The thermal plasma powers measured with a calorimeter in the chamber of PWK3 are presented, leading to thepossibility to determineefe ciencies. When thepowerwas varied, two discrete operational transitions were observed. The simultaneous differences in the discharge behavior of IPG3 are represented by sudden changes of parameters such as calorimetric powers and local heat e uxes measured with a stationary heat e ux probeinthechamberofthefacility. Additionally,thecoolingpoweroftheIPG3plasmatubeispresented.Here, a plasma stabilization effect appearing with the second operational transition was observed when the tube cooling power decreased suddenly despite the simultaneous increase of the plasma power in the chamber. An imaging spectrometer measuring the radial intensity of the plasma through an axial optical window of IPG3 was used. Both the operational behavior, in particular the stabilization effect, and the heat e ux measurements show that PWK3 enables high-enthalpy tests for both basic thermal protection material tests and atmospheric entry simulation of spacecrafts.
9