The International Journal of Periodontics & Restorative Dentistry · 2014 · 12 citations · 0 references
Tissue EngineeringBone RepairSurgeryOrthopaedic SurgeryOsteoporosisRegenerative MedicineExtraction SocketsSynthetic Bone SubstituteRegenerative BiomaterialsBone RemodelingOsteoarthritisHistomorphometric EvaluationVascularized Bone GraftMaxillofacial SurgeryCalcium Phosphosilicate PuttyVital BoneHealth SciencesBone DensityImplantologyBone MetabolismBone ImagingFracture HealingHard Tissue EngineeringMedicine
The objective of this study was to evaluate bone regeneration in 24 sockets grafted with a calcium phosphosilicate putty alloplastic bone substitute. A core was obtained from 17 sockets prior to implant placement for histomorphometry at 5 to 6 months postextraction. Radiographic analysis during the same postextraction healing period showed radiopaque tissue in all sockets. Histomorphometric analysis revealed a mean vital bone content of 31.76% (± 14.20%) and residual graft content of 11.47% (± 8.99%) after a mean healing period of 5.7 months. The high percentage of vital bone in the healed sites in combination with its timely absorption rate suggest that calcium phosphosilicate putty can be a reliable choice for osseous regeneration in extraction sockets.