Journal of Analytical Toxicology · 2016 · 39 citations · 21 references
Natural SciencesChemistryToxicologyAnalytical ChemistryAnalytical ToxicologyMass Spectrometric AnalysisAnalytical ChromatographyChromatographyContaminant AnalysisInstrumental AnalysisMass SpectrometryIsotope DilutionIsotope Dilution AnalysisIsotope Dilution Mass SpectrometryLiquid Chromatography-mass Spectrometry AnalysisLiquid Chromatography-mass Spectrometry Method DevelopmentReversed-phase Solid-phase ExtractionStable Isotope Dilution AnalysisTandem Mass Spectrometry Analysis
Chlorine is a public health concern and potential threat due to its high reactivity, ease and scale of production, widespread industrial use, bulk transportation, massive stockpiles and history as a chemical weapon. This work describes a new, sensitive and rapid stable isotope dilution method for the retrospective detection and quantitation of two chlorine adducts. The biomarkers 3-chlorotyrosine (Cl-Tyr) and 3,5-dichlorotyrosine (Cl2-Tyr) were isolated from the pronase digest of chlorine exposed whole blood, serum or plasma by solid-phase extraction (SPE), separated by reversed-phase HPLC and detected by tandem mass spectrometry (MS-MS). The calibration range is 2.50-1,000 ng/mL (R2 ≥ 0.998) with a lowest reportable limit (LRL) of 2.50 ng/mL for both analytes, an accuracy of ≥93% and an LOD of 0.443 ng/mL for Cl-Tyr and 0.396 ng/mL for Cl2-Tyr. Inter- and intra-day precision of quality control samples had coefficients of variation of ≤10% and ≤7.0%, respectively. Blood and serum samples from 200 healthy individuals and 175 individuals with chronic inflammatory disease were analyzed using this method to assess background levels of chlorinated tyrosine adducts. Results from patients with no known inflammatory disease history (healthy) showed baseline levels of <LRL-4.26 ng/mL Cl-Tyr and <LRL Cl2-Tyr. Patients with inflammatory disease had baseline levels of <LRL-15.4 ng/mL Cl-Tyr and <LRL-5.22 ng/mL Cl2-Tyr. Blood exposed to 2.02 ppm chlorine gas for 15 min produced 941 ng/mL Cl-Tyr and 223 ng/mL Cl2-Tyr. This high-throughput method has been developed and analytically validated for the diagnosis of human exposure to chlorine.
21
Stanley L. Hazen, Jay W. Heinecke · Journal of Clinical Investigation · 1997 · 843 citations · Full text
Quality assurance of chemical measurements
J.K. Taylor, Roy L. Tranter · Analytica Chimica Acta · 1989 · 689 citations
Human neutrophils employ chlorine gas as an oxidant during phagocytosis.
Stanley L. Hazen, Fong‐Fu Hsu, David M. Mueller et al. · Journal of Clinical Investigation · 1996 · 258 citations · Full text