Journal of Endovascular Therapy · 2016 · 37 citations · 18 references
MedicineRadiologySurgeryDiagnostic ImagingDiagnostic RadiologyVascular SurgeryAneurysm RepairEquivalent DosePatient-specific DosimetryRadiation Dose MeasurementRadiation TherapyDose Reduction TechniquesEndovascular Aortic Aneurysm RepairEndovascular Vascular RepairFluoroscopic GuidanceFluoroscopy Dose ReductionRadiation Dose AssessmentRadiation Dose ReductionRadiation Reduction
PURPOSE: To evaluate the effect of radiation dose reduction with the Allura ClarityIQ image processing technology for fixed C-arms in comparison with a mobile C-arm and an Allura fixed C-arm without ClarityIQ technology during endovascular aneurysm repair (EVAR) procedures. METHODS: Radiation dose data from 85 patients (mean age 74.2±7.8 years; 68 men) undergoing EVAR with mobile and fixed C-arm fluoroscopy were retrospectively analyzed. The radiation dose parameters included the kerma area product (KAP), fluoroscopic time (FT), and number of digital subtraction angiography (DSA) frames (FrDSA). KAPtotal consisted of KAPfluoro (KAP for fluoroscopic imaging) and KAPDSA (KAP for DSA and single shots). Linear regression analysis was used to explore differences in the association of KAP with the FT, FrDSA, and body mass index (BMI) among the 3 C-arms. RESULTS: The mean KAPtotal values for mobile, Allura C-arm, and AlluraClarity C-arm for noncomplex EVARs were 56±39, 245±142, and 157±120 Gy·cm(2) (p<0.001); for complex EVARs, the values were 110±43, 874±653, and 598±319 Gy·cm(2) (p<0.001), respectively. On average, KAPfluoro tripled when the mobile C-arm was replaced by the fixed C-arm. There were no significant differences in the KAPfluoro adjusted for the FT between Allura and AlluraClarity (p=0.69). However, there was a major 61% reduction in KAPDSA from 1.36 Gy·cm(2) per DSA frame for Allura to 0.54 Gy·cm(2) per DSA frame with AlluraClarity (p=0.03). For the mobile C-arm, BMI was not associated with KAP (p=0.13). The associations of BMI with KAPfluoro and KAPDSA were significant for both fixed C-arms but were more robust for Allura compared to AlluraClarity (p=0.02 for KAPfluoro and p<0.001 for KAPDSA). CONCLUSION: Changing a mobile C-arm for a fixed C-arm in a hybrid operating suite increased the average intraoperative dose during EVAR. Upgrading the Allura fixed C-arm with ClarityIQ technology resulted in a 61% reduction in the radiation per DSA frame.
18
Guidelines for Patient Radiation Dose Management
Stephen Balter, Richard B. Towbin, Donald L. Miller et al. · Journal of Vascular and Interventional Radiology · 2009 · 441 citations
Vania Tacher, MingDe Lin, Pascal Desgranges et al. · Journal of Vascular and Interventional Radiology · 2013 · 157 citations
Giuseppe Panuccio, Roy K. Greenberg, Kevin Wunderle et al. · Journal of Vascular Surgery · 2011 · 101 citations · Full text