Robust Matrix Converter Commutation without explicit Sign Measurement

J. Mahlein, Jens Igney, Michael Braun, Olaf Simon

2001 · 10 citations · 5 references

Concepts

Abstract

A new operation method for matrix converters is presented which eliminates the extra measuring circuits of voltage or current signs that were necessary for the commutation in the past. The paper explains the new robust method that minimises switching losses. Advantages and disadvantages of different approaches are discussed and measurements on a 5.5 kW matrix converter system are shown.

References

5