Journal of Neurosurgical Anesthesiology · 2016 · 84 citations · 32 references
MedicineNeurological SurgeryNeuroanesthesiologyPulmonary Function TestingPulmonologyIntracranial HypertensionIntracranial Pressure MonitoringPositive End-expiratory PressureIncreased Intracranial PressureNoninvasive Intracranial Pressure EstimationNoninvasive Intracranial Pressure MonitoringOptic Nerve Sheath Diameter MeasurementOptic Nerve Sheath Diameter MonitoringProne PositioningRespiratory MechanicsRespiratory System Mechanics
BACKGROUND: Prone positioning and positive end-expiratory pressure can improve pulmonary gas exchange and respiratory mechanics. However, they may be associated with the development of intracranial hypertension. Intracranial pressure (ICP) can be noninvasively estimated from the sonographic measurement of the optic nerve sheath diameter (ONSD) and from the transcranial Doppler analysis of the pulsatility (ICPPI) and the diastolic component (ICPFVd) of the velocity waveform. METHODS: The effect of the prone positioning and positive end-expiratory pressure on ONSD, ICPFVd, and ICPPI was assessed in a prospective study of 30 patients undergoing spine surgery. One-way repeated measures analysis of variance, fixed-effect multivariate regression models, and receiver operating characteristic analyses were used to analyze numerical data. RESULTS: The mean values of ONSD, ICPFVd, and ICPPI significantly increased after change from supine to prone position. Receiver operating characteristic analyses demonstrated that, among the noninvasive methods, the mean ONSD measure had the greatest area under the curve signifying it is the most effective in distinguishing a hypothetical change in ICP between supine and prone positioning (0.86±0.034 [0.79 to 0.92]). A cutoff of 0.43 cm was found to be a best separator of ONSD value between supine and prone with a specificity of 75.0 and a sensitivity of 86.7. CONCLUSIONS: Noninvasive ICP estimation may be useful in patients at risk of developing intracranial hypertension who require prone positioning.
32
Arterial assessment by Doppler-shift ultrasound.
R.G. Gosling, D. H. King · PubMed · 1974 · 667 citations
Luciano Gattinoni, Paolo Pelosi, Stefania Crotti et al. · American Journal of Respiratory and Critical Care Medicine · 1995 · 581 citations
Transcranial Doppler sonography pulsatility index (PI) reflects intracranial pressure (ICP)
Johan Bellner, Bertil Romner, Peter Reinstrup et al. · Surgical Neurology · 2004 · 525 citations
Medicine, Neurology, Neurosurgery +13