PubMed · 1976 · 12 citations · 0 references
MedicineGynecologySurgeryBiomedical OpticsBiophotonicsMicrosurgeryAbsorption In TissueBiomedical Laser ApplicationsLaser SurgeryLaser-tissue InteractionMinimally Invasive SurgeryVaginal SurgeryCarbon Dioxide Laser SurgeryLaser Beam FocusingLaser Surgery SystemsMicrosurgical Laser InstrumentsVaginal Creams
A carbon dioxide laser microsurgical system was used in the treatment of the 38 cases of vaginal adenosis and related cervicovaginal disorders. The laser continuously generates a quasi-parallel beam of electromagnetic radiation in the infrared portion of the spectrum at a 10.6 micron wavelength. The entire thermal energy carried by this beam can be focused by a lens into a small spot where a high energy density is obtained. This energy is absorbed by all soft body tissues hence is nonpenetrating. Tissue damage is thermal and localized. The rate of tissue removal is controlled visually by adjusting the power output. Precise control of tissue destruction is obtained. Adjacent damage up to 100 microns and thermal necrosis to a depth of 500 microns has been shown. Excellent healing follows laser surgery. Bleeding is not a problem. The instrumentation is attached directly to a Zeiss colposcope. The laser beam can be focused on any tissue within the colposcopic field. A 3% acetic acid solution is applied to delineate the area to be removed. Vaginal packing vaginal creams or douches are not used. Monthly reexaminations are recommended for 3 months after which quarterly examinations and then semiannual examinations. Neither vaginal synechia or constrictions or dyspareunia have developed. In the 1 pregnancy that followed the vaginal epithelium appeared normal.