Publication | Open Access
Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trial
90
Citations
18
References
2016
Year
MIS-RDAVR is associated with a significantly reduced cross-clamp time and better valvular haemodynamic function than FS-AVR. However, paravalvular leak rates are higher with MIS-RDAVR.