How to calculate the main aortic graft-diameter for a chimney-graft.

Tilo Kölbel, Sebastian Carpenter, Anusch Taraz, Martin Taraz, A. Larena-Avellaneda, Eike Sebastian Debus

PubMed · 2013 · 13 citations · 0 references

Concepts

Abstract

Aim: The aim of this paper was to present a mathematical model to calculate the required main aortic graft-diameter for parallel chimney-grafts. Methods: Geometric approximation model, developed to allow for a standardized calculation of the main aortic graft-diameter determined by the aortic diameter and the diameter of the chimney-graft. Results: We propose a mathematical formula using circular segments of the aorta and the chimney-graft and provide a table with recommended main aortic graft-diameters for single chimney-grafts of 6 and 8 mm. Conclusion: Geometric approximation can be used to calculate the required main aortic graft-diameter. For parallel running chimney-grafts a significant degree of oversizing is necessary to allow the main aortic body to surround the chimney and to prevent the occurrence of gutters, which may cause type-1 endoleaks.