SAE technical papers on CD-ROM/SAE technical paper series · 2000 · 10 citations · 2 references
EngineeringAutomotive EngineeringMechanical EngineeringHeat TransferInternal Combustion EnginesThermodynamicsEngine CoolingEngine Cooling SystemsEngine EfficiencyEngine Heat TransferExhaust SystemsHeat Transfer ModelingCombustion Chamber Heat TransferEngine Thermal ModelingExhaust Thermal ManagementHeat Transfer During CombustionHeat Transfer In PipesIn-cylinder Heat Transfer
<div class="htmlview paragraph">This study shows the measurement and calculation of exhaust heat exchange coefficient in a pipe of internal combustion engine. A specific exhaust-air heat exchanger has been installed on the exhaust line of engine. The Nusselt-Reynolds correlation has been developed and compared to the steady state conditions. The Convective Augmentation Factor (CAF) is approximately 2 at low Reynolds number and 1 at high Reynolds number. The EGR cooler and the exhaust-coolant heat exchanger for improving the passenger compartment heating have been shown.</div>
2