2015 · 21 citations · 7 references
EngineeringBioengineeringBiomedical EngineeringBiomedical Signal ProcessingFeature EngineeringTime Series AnalysisBlood Pressure Signal AnalysisCardiac Signal ProcessingCardiovascular MonitoringDigital Signal ProcessingVital SignsVital Signs AssessmentArterial Blood Pressure MeasurementArterial Blood Pressure Waveform AnalysisPeak DetectionPositive Predictive ValuePulse Wave AnalysisRobust DetectionSingular Value DecompositionWavelet Transform
The paper presents a technique to detect significant systolic peaks, the percussion (P) and tidal peak (T) and diastolic peak (D) from the arterial blood pressure (ABP) waveform. The technique is aimed at robust detection even in presence of significant noise. Singular Value Decomposition (SVD) based dominant period extraction of the ABP waveform followed by wavelet transform and local peak detection is applied to detect the points of interest. MIMIC-II ABP databse serves as a training dataset to select SVD and wavelet transform parameters and CSL Benchmark database is used to analyze the technique. Salient systolic peak detection for the CSL dataset was performed with positive predictive value and sensitivity figures of 98.48% and 99.24% respectively.
7
An Automatic Beat Detection Algorithm for Pressure Signals
Mateo Aboy, James McNames, T. Thong et al. · IEEE Transactions on Biomedical Engineering · 2005 · 206 citations