2010 · 43 citations · 10 references
EngineeringElectrical EngineeringEnergy SystemsRenewable Energy IntegrationRenewable Energy SystemsEnergy EfficiencyPhotovoltaic DevicesRenewable EnergySolar CellsSolar Energy SystemsSolar Photovoltaic SystemsEfficiencyMaximum Power OutputOutput EfficiencyPhotovoltaic Energy SystemsPhotovoltaic SystemsPower Conversion EfficiencyPower OutputSolar Photovoltaic Power Systems
Lately, the use of solar energy has seen considerable development. Transformation in electric energy is one of its applications which attracts considerable interest, owing to the fact that it makes it possible to solve a major problem in isolated cities that lack electrical supply networks. For solar energy use, the current drawback remains its high cost. This problem can be resolved through different improvements in terms of power production. For that, different axis of research can be explored (1-3). Over the past few years, solar cells arrays (SCA) have been connected to various loads in a direct coupled method. A PV module can produce the power at a point, called an operating point, anywhere on the current- voltage (I-V) curve. The coordinates of the Operating point are the operating voltage and current. There is a unique point near the knee of the I-V curve, called a maximum power point (MPP), at which the module operates with the maximum efficiency and produces the maximum output power. The point of maximum power is the desired operating point for a PV array to obtain maximum efficiency. A PV array is usually oversized to compensate for a low power yield during winter months. This mismatching between a PV module and a load requires further over-sizing of the PV array and thus increases the overall system cost (3-5). To mitigate this problem, different methods have been developed (6-12). A maximum power point tracker (MPPT) can be used to maintain the PV module's operating point at the MPP. The system in a direct coupled method cannot always operate at maximum power point (MPP) of the solar array when the load, irradiance or temperature changes. A PV-load coupling system should be able to maximize the energy output of the PV generator, which should operate always at its maximum power point (MPP) in order to achieve maximum global efficiency. Some authors have supported the direct coupling between the PV generator and the load (2-3). Several methods and algorithms to track the maximum power point have been developed (2-12). We focused our effort on improving the matching between PV sources and loads through the development of new performing methods. In this paper, a rapid approach for peak power tracking is proposed. The system PV generator - load is optimized, when the working point in direct coupling is quite near the MPP of the PV generator, so that the global efficiency of the system is acceptable. Another method is proposed. It is based on reconfiguring on-line the SCA by changing the connections between different modules in
10