A Study of Particulate Matter in I.V. Infusion Fluids

Neil M. Davis, Salvatore J. Turco, Edward Sivelly

American Journal of Health-System Pharmacy · 1970 · 28 citations · 0 references

Concepts

Abstract

The presence of particulate matter in parenteral solutions has been a problem since the advent of this route of administration. This paper reports a study of particulate matter, using the Millipore membrane technique, in large volume I.V. solutions of four commercial manufacturers. Six different solutions and different batches of each manufacturer were investigated. Also studied were the effectiveness of a final filtration set and particulate matter in solutions combined with administration sets, in solutions with additives, and solutions in plastic containers. The results show considerable variation among different manufacturers and among different solutions and different lots of the same solution of a single manufacturer. The addition of devices or additives increased the number of particulates. The final filter set was very effective in removing participate matter. The solution in a plastic container contained fewer particles than those in glass containers.