Increased coagulation and fibrinolytic potential of solvent–detergent plasma: a comparative study between Omniplasma and fresh frozen plasma
13
Citations
24
References
2016
Year
Our results suggest an increased coagulation potential, presumingly as a result of contact activation during the production process and also, an increased fibrinolytic potential in Omniplasma. The stability of Omniplasma, based upon the different parameters studied, is comparable to Q-plasma. A maximum post-thawing time of 48 hfor Omniplasma can be suggested.