PubMed · 1994 · 45 citations · 0 references
MedicinePerioperative MedicineSurgeryCerebrovascular SurgeryMicrosurgeryVascular SurgeryCarotid Artery DiseaseCarotid Artery SurgeryCarotid EndarterectomyEndovascular SurgeryCarotid Artery AngioplastyCarotid Patch MaterialsIntraoperative Digital Subtraction AngiographyOperative TechniquePerioperative Stroke RiskSaphenous Vein GraftingShunt Use During Carotid Endarterectomy
Although carotid patch angioplasty has been performed on a selective or routine basis in all large series of carotid endarterectomy, the choice of patch material still remains in question. The objective of this study has been a prospective randomized evaluation of the relative risks and benefits of saphenous vein patch versus PTFE patch material for carotid endarterectomy. During a 4-year period, 84 patients undergoing 95 carotid endarterectomies were randomized into two groups: 45 venous patch (n = 40) and 50 PTFE patch (n = 44). All operations were carried out under general anesthesia and systematic placement of a shunt. The patients were evaluated at 1, 3, 6 months and every year with doppler, periorbitary photoplethysmography, intravenous digital subtraction angiography, and neurologic assessment (mean follow-up 29 +/- 1 month). Operative time among patients having PTFE patch was significantly longer (p < 0.05) than among those having saphenous vein patch, due to bleeding from suture holes. Perioperatively, no neurologic complications or deaths were observed in venous patch patients, however there was a permanent stroke and one death from arterial wall disruption in the PTFE patch group. The incidence of aneurysmal dilatation in the saphenous vein patch group (15.5%) was higher than for the PTFE patch group (2%). On late follow-up, no deaths, carotid thrombosis or patch rupture were observed in either group. Recurrent stenosis occurred in 2 cases having PTFE patch. One reoperation for recurrence was required. In addition, one patient with PTFE patch angioplasty developed an infected false aneurysm at 7 months.(ABSTRACT TRUNCATED AT 250 WORDS)