IEEE Transactions on Biomedical Engineering · 2015 · 192 citations · 36 references
EngineeringBioengineeringBiomedical EngineeringBiosensorsElectrochemistryElectrophysiologyBiopotential MeasurementElectrocardiographyElectrochemical SensorsElectrode-electrolyte InterfacesSmart TextilesWearable BiosensorsBiopotential ElectrodesBiopotential RecordingDry ElectrodesFabricationMixed Ionic-electronic ConductivityTextile-based SensingWearable Health MonitoringWet Electrodes
The study evaluates a novel textile ECG electrode made from woven fabrics treated with PSS, fabricated via soaking, dopant addition, squeezing, and annealing, to assess its suitability for biopotential recording. Human volunteer testing measured skin contact impedance and ECG signal quality at rest and during activity, demonstrating that the electrodes function in both wet and dry conditions. Results show that wet (saline) electrodes provide stable, reproducible ECG signals comparable or superior to conventional Ag/AgCl gelled electrodes, while dry electrodes suffer more noise during exercise; the PSS‑based textile electrodes offer effective, comfortable, and easy‑to‑fabricate wearable ECG monitoring without electrolyte, paving the way for smart garment integration.
To evaluate a novel kind of textile electrodes based on woven fabrics treated withPSS, through an easy fabrication process, testing these electrodes for biopotential recordings.Fabrication is based on raw fabric soaking inPSS using a second dopant, squeezing and annealing. The electrodes have been tested on human volunteers, in terms of both skin contact impedance and quality of the ECG signals recorded at rest and during physical activity (power spectral density, baseline wandering, QRS detectability, and broadband noise).The electrodes are able to operate in both wet and dry conditions. Dry electrodes are more prone to noise artifacts, especially during physical exercise and mainly due to the unstable contact between the electrode and the skin. Wet (saline) electrodes present a stable and reproducible behavior, which is comparable or better than that of traditional disposable gelled Ag/AgCl electrodes.The achieved results reveal the capability of this kind of electrodes to work without the electrolyte, providing a valuable interface with the skin, due to mixed electronic and ionic conductivity ofPSS. These electrodes can be effectively used for acquiring ECG signals.Textile electrodes based onPSS represent an important milestone in wearable monitoring, as they present an easy and reproducible fabrication process, very good performance in wet and dry (at rest) conditions and a superior level of comfort with respect to textile electrodes proposed so far. This paves the way to their integration into smart garments.
36
PhysioBank, PhysioToolkit, and PhysioNet
Ary L. Goldberger, Luı́s A. Nunes Amaral, Leon Glass et al. · Circulation · 2000 · 14.5K citations · Full text
A Real-Time QRS Detection Algorithm
Jiapu Pan, W.J. Tompkins · IEEE Transactions on Biomedical Engineering · 1985 · 7.7K citations
NeuroGrid: recording action potentials from the surface of the brain
Dion Khodagholy, Jennifer N. Gelinas, Thomas Thesen et al. · Nature Neuroscience · 2014 · 954 citations · Full text