Journal of neurosurgery · 2016 · 64 citations · 18 references
MedicineOphthalmologySurgeryOcular AnatomyOphthalmic SurgeryVascular SurgeryAneurysm SurgeryOphthalmic MicrosurgeryAnatomical CorrelationAneurysm Sac OcclusionAneurysm Surgical AnatomyDevice EmbolizationIntraoperative Digital Subtraction Angiography
OBJECTIVE Contemporary treatment for paraophthalmic artery aneurysms includes flow diversion utilizing the Pipeline Embolization Device (PED). Little is known, however, about the potential implications of the anatomical relationship of the ophthalmic artery (OA) origin and aneurysm, especially in smaller aneurysms. METHODS Four major academic institutions in the United States provided data on small paraophthalmic aneurysms (≤ 7 mm) that were treated with PED between 2009 and 2015. The anatomical relationship of OA origin and aneurysm, radiographic outcomes of aneurysm occlusion, and patency of the OA were assessed using digital subtraction angiography. OA origin was classified as follows: Type 1, OA separate from the aneurysm; Type 2, OA from the aneurysm neck; and Type 3, OA from the aneurysm dome. Clinical outcome was assessed using the modified Rankin Scale, and visual deficits were categorized as transient or permanent. RESULTS The cumulative number of small paraophthalmic aneurysms treated with PED between 2009 and 2015 at the 4 participating institutions was 69 in 52 patients (54.1 ± 13.7 years of age) with a male-to-female ratio of 1:12. The distribution of OA origin was 72.5% for Type 1, 17.4% for Type 2, and 10.1% for Type 3. Radiographic outcome at the last follow-up (median 11.5 months) was available for 54 aneurysms (78.3%) with complete, near-complete, and incomplete occlusion rates of 81.5%, 5.6%, and 12.9%, respectively. Two aneurysms (3%) resulted in transient visual deficits, and no patient experienced a permanent visual deficit. At the last follow-up, the OA was patent in 96.8% of treated aneurysms. Type 3 OA origin was associated with a lower rate of complete aneurysm occlusion (p = 0.0297), demonstrating a trend toward visual deficits (p = 0.0797) and a lower rate of OA patency (p = 0.0783). CONCLUSIONS Pipeline embolization treatment of small paraophthalmic aneurysms is safe and effective. An aneurysm where the OA arises from the aneurysm dome may be associated with lower rates of aneurysm occlusion, OA patency, and higher rates of transient visual deficits.
18
The Natural Course of Unruptured Cerebral Aneurysms in a Japanese Cohort
New England Journal of Medicine · 2012 · 1.5K citations · Full text
Medicine, Neurosurgery, Surgery +16
The Barrow Ruptured Aneurysm Trial
Cameron G. McDougall, Robert F. Spetzler, Joseph M. Zabramski et al. · Journal of neurosurgery · 2011 · 641 citations
Lifelong Rupture Risk of Intracranial Aneurysms Depends on Risk Factors
Miikka Korja, Hanna Lehto, Seppo Juvela · Stroke · 2014 · 289 citations · Full text
Medicine, Neurosurgery, Surgery +16
High-Profile Flow Diverter (Silk) Implantation in the Basilar Artery
Zsolt Kulcsár, Ulrike Ernemann, Stephan G. Wetzel et al. · Stroke · 2010 · 218 citations · Full text
Medicine, Neurosurgery, Surgery +12