Clinical ophthalmology · 2016 · 16 citations · 29 references
MedicineOphthalmologySurgeryClinical OptometryOphthalmic SurgeryRefractive SurgeryAstigmatism CorrectionCataract ManagementCataract SurgeryPostoperative Refractive OutcomesPreoperative Refractive EvaluationRefractive ErrorAstigmatic CorrectionAstigmatic OutcomeAstigmatismCataract Surgery Astigmatism ManagementIol Power CalculationPostoperative AstigmatismPostoperative Refractive StabilitySurgical Astigmatism
PURPOSE: The purpose of this study was to evaluate the visual and refractive outcomes and rotational stability of the new aspheric Precizon(®) toric intraocular lens (IOL) for the correction of corneal astigmatism in cataract surgery. SETTING: Department of Ophthalmology, Hospital Geral de Santo António - Centro Hospitalar do Porto, EPE and Hospital de Pedro Hispano, Matosinhos, Portugal. DESIGN: This was a prospective clinical study. PATIENTS AND METHODS: A total of 40 eyes of 27 patients with corneal astigmatism greater than 1.0 diopter (D) underwent cataract surgery with implantation of Precizon(®) toric IOL. IOL power calculation was performed using optical coherence biometry (IOLMaster(®)). Outcomes of uncorrected (UDVA) and best-spectacle corrected distance visual acuities (BCDVA), refraction, and IOL rotation were analyzed at the 1st week, 1st, 3rd, and 6th month's evaluations. RESULTS: The median postoperative UDVA was better than preoperative best-spectacle corrected distance visual acuity (0.02 [0.06] logMAR vs 0.19 [0.20] logMAR, P<0.001). At 6 months, postoperative UDVA was 0.1 logMAR or better in 95% of the eyes. At last follow-up, the mean spherical equivalent was reduced from -3.35±3.10 D to -0.02±0.30 D (P<0.001) with 97.5% of the eyes within ±0.50 D of emmetropia. The mean preoperative keratometric cylinder was 2.34±0.95 D and the mean postoperative refractive cylinder was 0.24±0.27 D (P<0.001). The mean IOL rotation was 2.43°±1.55°. None of the IOLs required realignment. CONCLUSION: Precizon(®) toric IOL revealed very good rotational stability and performance regarding predictability, efficacy, and safety in the correction of preexisting regular corneal astigmatism associated with cataract surgery.
29
Prevalence of Refractive Error in the United States, 1999-2004
Susan Vitale · Archives of Ophthalmology · 2008 · 509 citations
Medicine, Ophthalmology, Optometry +14
Biometry of 7,500 Cataractous Eyes
Kenneth J. Hoffer · American Journal of Ophthalmology · 1980 · 427 citations
Gains from cataract surgery: visual function and quality of life.
Parul Desai, A Reidy, Darwin Minassian et al. · British Journal of Ophthalmology · 1996 · 228 citations · Full text
Medicine, Ophthalmology, Surgery +17