Analytical Chemistry · 2016 · 84 citations · 34 references
PharmacyBiochemistryAnalytical ChemistryChromatographic AnalysisMass Spectrometric AnalysisAccurate Mass MeasurementInstrumental AnalysisLiquid ChromatographyMass SpectrometryMetabolite QuantificationAccuracyFalse Negative DetectionHigh-resolution Mass AnalysisLiquid Chromatography-mass SpectrometryLiquid Chromatography-mass Spectrometry AnalysisMass Spectrometric QuantificationRelative Metabolite QuantificationRelative Quantification
A paradigm shift is underway in the field of quantitative liquid chromatography-mass spectrometry (LC-MS) analysis thanks to the arrival of recent high-resolution mass spectrometers (HRMS). The capability of HRMS to perform sensitive and reliable quantifications of a large variety of analytes in HR-full scan mode is showing that it is now realistic to perform quantitative and qualitative analysis with the same instrument. Moreover, HR-full scan acquisition offers a global view of sample extracts and allows retrospective investigations as virtually all ionized compounds are detected with a high sensitivity. In time, the versatility of HRMS together with the increasing need for relative quantification of hundreds of endogenous metabolites should promote a shift from triple-quadrupole MS to HRMS. However, a current "pitfall" in quantitative LC-HRMS analysis is the lack of HRMS-specific guidance for validated quantitative analyses. Indeed, false positive and false negative HRMS detections are rare, albeit possible, if inadequate parameters are used. Here, we investigated two key parameters for the validation of LC-HRMS quantitative analyses: the mass accuracy (MA) and the mass-extraction-window (MEW) that is used to construct the extracted-ion-chromatograms. We propose MA-parameters, graphs, and equations to calculate rational MEW width for the validation of quantitative LC-HRMS methods. MA measurements were performed on four different LC-HRMS platforms. Experimentally determined MEW values ranged between 5.6 and 16.5 ppm and depended on the HRMS platform, its working environment, the calibration procedure, and the analyte considered. The proposed procedure provides a fit-for-purpose MEW determination and prevents false detections.
34
Induction and detoxification of maize 1,4‐benzoxazin‐3‐ones by insect herbivores
Gaétan Glauser, Guillaume Marti, Neil Villard et al. · The Plant Journal · 2011 · 250 citations · Full text
Amina Haouala, Boris Zanolari, Bertrand Rochat et al. · Journal of Chromatography B · 2009 · 202 citations
Pharmacy, Oncology, Pharmacology +16
Markus Kellmann, Helmut Muenster, Paul Zomer et al. · Journal of the American Society for Mass Spectrometry · 2009 · 192 citations · Full text
Anton Kaufmann, Patrick Butcher, Kathryn Maden et al. · Analytica Chimica Acta · 2010 · 184 citations