LUTPub (LUT University) · 2013 · 16 citations · 0 references
Open access
EngineeringElectrical EngineeringElectric MachinesElectromagneticsElectromagnetismGenerator OperationLosses In Electric MachinesMagnetic Circuit AnalysisMagnetic ComponentsPermanent Magnet MachinesPower QualityCore Loss AnalysisEddy Current LossesIron LossesLoss AnalysisPermanent Magnet Losses
Permanent magnet generators (PMG) represent the cutting edge technology in modern wind \nmills. The efficiency remains high (over 90%) at partial loads. To improve the machine \nefficiency even further, every aspect of machine losses has to be analyzed. Additional losses \nare often given as a certain percentage without providing any detailed information about the \nactual calculation process; meanwhile, there are many design-dependent losses that have an \neffect on the total amount of additional losses and that have to be taken into consideration. \nAdditional losses are most often eddy current losses in different parts of the machine. These \nlosses are usually difficult to calculate in the design process. In this doctoral thesis, some \nadditional losses are identified and modeled. Further, suggestions on how to minimize the \nlosses are given. \nIron losses can differ significantly between the measured no-load values and the loss values \nunder load. In addition, with embedded magnet rotors, the quadrature-axis armature reaction \nadds losses to the stator iron by manipulating the harmonic content of the flux. It was, \ntherefore, re-evaluated that in salient pole machines, to minimize the losses and the loss \ndifference between the no-load and load operation, the flux density has to be kept below 1.5 \nT in the stator yoke, which is the traditional guideline for machine designers. \nEddy current losses may occur in the end-winding area and in the support structure of the \nmachine, that is, in the finger plate and the clamping ring. With construction steel, these \nlosses account for 0.08% of the input power of the machine. These losses can be reduced \nalmost to zero by using nonmagnetic stainless steel. In addition, the machine housing may be \nsubjected to eddy current losses if the flux density exceeds 1.5 T in the stator yoke. \nWinding losses can rise rapidly when high frequencies and 10–15 mm high conductors are \nused. In general, minimizing the winding losses is simple. For example, it can be done by dividing the conductor into transposed subconductors. However, this comes with the expense \nof an increase in the DC resistance. In the doctoral thesis, a new method is presented to \nminimize the winding losses by applying a litz wire with noninsulated strands. The \nconstruction is the same as in a normal litz wire but the insulation between the subconductors \nhas been left out. The idea is that the connection is kept weak to prevent harmful eddy \ncurrents from flowing. Moreover, the analytical solution for calculating the AC resistance \nfactor of the litz-wire is supplemented by including an end-winding resistance in the \nanalytical solution. A simple measurement device is developed to measure the AC resistance \nin the windings. In the case of a litz-wire with originally noninsulated strands, vacuum \npressure impregnation (VPI) is used to insulate the subconductors. In one of the two cases \nstudied, the VPI affected the AC resistance factor, but in the other case, it did not have any \neffect. However, more research is needed to determine the effect of the VPI on litz-wire with \nnoninsulated strands. \nAn empirical model is developed to calculate the AC resistance factor of a single-layer formwound \nwinding. The model includes the end-winding length and the number of strands and \nturns. The end winding includes the circulating current (eddy currents that are traveling \nthrough the whole winding between parallel strands) and the main current. The end-winding \nlength also affects the total AC resistance factor.