Clinical and Applied Thrombosis/Hemostasis · 1999 · 81 citations · 17 references
MedicineCardiologyHematologyClinical PharmacologyHemostasisInterventional CardiologyAnticoagulant TherapyAntiplatelet TherapyPlatelet AdhesionPlatelet AggregationPlatelet FunctionThrombosisAnticoagulation During Coronary InterventionAntiplatelet DrugsAntiplatelet Therapy After Percutaneous Coronary InterventionCoronary Balloon AngioplastyPlatelet Adhesion AssaysShear-dependent Platelet AdhesionShear-dependent Platelet FunctionWhole Blood Collection
The platelet function analyzer (PFA)-100 is a newly developed instrument that provides a rapid, in vitro, quantitative measurement of platelet adhesion and aggregation in whole blood flowing through a small aperture under high shear conditions. Thirty patients undergoing percutaneous transluminal coronary angioplasty (PTCA) and ten normal individuals were included in this study. In vitro and in vivo studies were conducted to discern the effect of combinations of antiplatelet drugs (aspirin, ticlopidine, abciximab) and heparin on the performance of the device as well as the effects of preanalytical variables, such as method of sample collection and ex vivo anticoagulants. Studies were also conducted examining the effect of aperture size (standard 150 microns vs. smaller 120 microns) on the ability of the device to detect the effect of antiplatelet drugs. There was no difference in mean PFA-100 closure time with citrate versus PPACK anticoagulants or with venipuncture vs. sheath sampling. Closure times did not vary with heparin administration. Closure times were slightly longer for patients taking aspirin plus ticlopidine compared to aspirin alone (p = NS). In contrast adenosine disphosphate (ADP) induced platelet aggregation was significantly less in patients that took aspirin plus ticlopidine vs. aspirin alone (p = .0005). In vitro, there was a dose-dependent increase in closure time for both aperture sizes with increasing abciximab concentration. Although both cartridges showed infinite closure times at an abciximab concentration of 2.25 micrograms/mL, there was a slight benefit to using the 120 microns aperture cartridges at abciximab concentrations of 1.75 to 2.0 micrograms/mL. In ten patients who were followed during abciximab therapy to assess the effect of aperture size, the PFA-100 was able to detect in vivo platelet inhibition by abciximab, but detection of recovery from abciximab-induced platelet dysfunction was slightly better for the PFA-100 with the 120 microns aperture compared to the standard 150 microns aperture collagen/ADP cartridge.
17
Édith Fressinaud, Agnès Veyradier, F Truchaud et al. · Blood · 1998 · 320 citations · Full text
Robert A. Harrington, Neal S. Kleiman, Kandice Kottke‐Marchant et al. · The American Journal of Cardiology · 1995 · 213 citations
Medicine, Cardiology, Pharmacology +17