Journal of Nuclear Medicine · 2016 · 106 citations · 16 references
MedicineNuclear MedicineOncologyGastrointestinal OncologyOncologic Nuclear MedicineRadionuclide TherapyLiver MetastasisMetastatic Disease ManagementRadiation TherapyTumor ImagingColorectal Liver MetastasisGlycolysisHepatobiliary Cancer Systemic TherapyLiver Metastases TreatmentLiver Metastasis Response AssessmentMetastatic Liver Disease TreatmentPhase Ii Clinical TrialsProspective Cohort Data
UNLABELLED: Randomized controlled trials are investigating the benefit of hepatic radioembolization added to systemic therapy in the first- and second-line treatment of patients with colorectal liver metastases (CRLM). Remarkably, administered activity may still be suboptimal, because a dose-response relationship has not been defined. The purpose of this study was to characterize the relationship between tumor-absorbed dose and response after (90)Y radioembolization treatment for CRLM. METHODS: Thirty patients with unresectable chemorefractory CRLM were treated with resin (90)Y-microspheres in a prospective phase II clinical trial. Tumor-absorbed dose was quantified on (90)Y PET. Metabolic tumor activity, defined as tumor lesion glycolysis (TLG*) on (18)F-FDG PET, was measured at baseline and 1 mo after treatment. The relationship between tumor-absorbed dose and posttreatment metabolic activity was assessed per metastasis with a linear mixed-effects regression model. RESULTS: Treated metastases (n = 133) were identified. The mean tumor-absorbed dose was 51 ± 28 Gy (range, 7-174 Gy). A 50% reduction in TLG* was achieved in 46% of metastases and in 11 of 30 (37%) patients for the sum of metastases. The latter was associated with a prolonged median overall survival (11.6 vs. 6.6 mo, P = 0.02). A strong and statistically significant dose-response relationship was found (P < 0.001). The dose effect depended on baseline TLG* (P < 0.01). The effective tumor-absorbed dose was conservatively estimated at a minimum of 40-60 Gy. CONCLUSION: A strong dose-response relationship exists for the treatment of CRLM with resin microsphere (90)Y radioembolization. Treatment efficacy is, however, still limited, because the currently used pretreatment activity calculation methods curb potentially achievable tumor-absorbed dose values. A more personalized approach to radioembolization is required before concluding on its clinical potential.
16
Erik von Elm, Douglas G. Altman, Matthias Egger et al. · Annals of Internal Medicine · 2007 · 17.2K citations
Public Health, Public Health Practice, Epidemiologic Methods +10
Erik von Elm, Douglas G. Altman, Matthias Egger et al. · Journal of Clinical Epidemiology · 2008 · 16.4K citations · Full text
Public Health, Public Health Practice, Epidemiologic Methods +10
Francesco Giammarile, Lisa Bodei, Carlo Chiesa et al. · European Journal of Nuclear Medicine and Molecular Imaging · 2011 · 231 citations · Full text
Yung Hsiang Kao, Andrew Eik Hock Tan, Mark C. Burgmans et al. · Journal of Nuclear Medicine · 2012 · 162 citations
Patrick Flamen, Bruno Vanderlinden, Philippe Delatte et al. · Physics in Medicine and Biology · 2008 · 150 citations
Medicine, Nuclear Medicine, Oncology +16