Journal of Analytical Toxicology · 1983 · 49 citations · 3 references
PharmacyPharmaceutical AnalysisPharmacologyAnalytical ToxicologyChromatographic AnalysisMetabolomicsCannabinoid PharmacologyCannabis ToxicologyCarboxylic AcidsChromatographic Analysis Of PharmaceuticalsChromatographyLiquid ChromatographyBlood Cannabinoid AnalysisCannabinoid Analytical ToxicologyCannabinoid BiomarkersCannabinoid DetectionHigh-performance Liquid ChromatographyInternal Standard AnalysisReversed-phase ColumnsUltraviolet Detector Technology
A high performance liquid chromatographic (HPLC) procedure was developed for the analysis of 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid in urine. Hydrolyzed urine samples were cleaned up using Bond-Elut columns. 11-Nor-cannabinol-9-carboxylic acid was used as internal standard. The analysis was carried out using a C8 reversed-phase column with acetonitrile:50 mM phosphoric acid (65:35) as the solvent. Detection was done by ultraviolet detector at 214 nm. The minimum detectable level of 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid was 25 ng/mL.
3
RADIOIMMUNOASSAY OF CANNABINOIDS IN BLOOD AND URINE
J D Teale, Laurence J. King, ElvyneJ. Forman et al. · The Lancet · 1974 · 48 citations
Marijuana metabolites in urine of man
Saul L. Κanter, Leo E. Hollister, Jose U. Zamora · Journal of Chromatography A · 1982 · 15 citations
Pharmacy, Pharmacology, Toxicology +11