EP Europace · 2016 · 15 citations · 10 references
MedicineBiomedical EngineeringCardiologyDiagnostic ImagingElectrophysiologyInterventional CardiologyCardiac ImagingCatheter AblationIntracardiac ElectrophysiologyMagnetic Resonance ImagingMedical ImagingMedical Imaging InstrumentationAblation SafetyAtrial Fibrillation ImagingAtrial Fibrillation MappingAtrial Flutter AblationCardiac ExaminationCatheter Ablation MappingIntracardiac MappingSignal-to-noise Ratio
AIMS: Interventional cardiac catheter mapping is routinely guided by X-ray fluoroscopy, although radiation exposure remains a significant concern. Feasibility of catheter ablation for common flutter has recently been demonstrated under magnetic resonance imaging (MRI) guidance. The benefit of catheter ablation under MRI could be significant for complex arrhythmias such as atrial fibrillation (AF), but MRI-compatible multi-electrode catheters such as Lasso have not yet been developed. This study aimed at demonstrating the feasibility and safety of using a multi-electrode catheter [magnetic resonance (MR)-compatible Lasso] during MRI for cardiac mapping. We also aimed at measuring the level of interference between MR and electrophysiological (EP) systems. METHODS AND RESULTS: Experiments were performed in vivo in sheep (N = 5) using a multi-electrode, circular, steerable, MR-compatible diagnostic catheter. The most common MRI sequences (1.5T) relevant for cardiac examination were run with the catheter positioned in the right atrium. High-quality electrograms were recorded while imaging with a maximal signal-to-noise ratio (peak-to-peak signal amplitude/peak-to-peak noise amplitude) ranging from 5.8 to 165. Importantly, MRI image quality was unchanged. Artefacts induced by MRI sequences during mapping were demonstrated to be compatible with clinical use. Phantom data demonstrated that this 10-pole circular catheter can be used safely with a maximum of 4°C increase in temperature. CONCLUSIONS: This new MR-compatible 10-pole catheter appears to be safe and effective. Combining MR and multipolar EP in a single session offers the possibility to correlate substrate information (scar, fibrosis) and EP mapping as well as online monitoring of lesion formation and electrical endpoint.
10
Cardiac Three-Dimensional Magnetic Resonance Imaging and Fluoroscopy Merging
Joris Ector, Stijn De Buck, Jef Adams et al. · Circulation · 2005 · 101 citations · Full text
Medicine, Cardiology, Radiology +17
Feasibility of real-time magnetic resonance imaging-guided electrophysiology studies in humans
Philipp Sommer, Matthias Grothoff, Charlotte Eitel et al. · EP Europace · 2012 · 82 citations · Full text
Medicine, Cardiology, Radiology +17