A High-Sensitivity Potentiometric Mercuric Ion Sensor Based on m-Toluidine Films

55

Citations

32

References

2015

Year

Abstract

A sensor of m-toluidine polymer film coated platinum electrode was fabricated by the electropolymerization using cyclic voltammetry technique for the detection of mercury ions (Hg <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> ) in aqueous solution. This paper was carried out using the simple potentiometric method and confirmed by a cyclic voltammetry technique. The effects of the polymer film thickness and pH of Hg <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> solutions on the response of the sensor were studied. Moreover, the stability, sensitivity, and selectivity of the m-toluidine sensor were investigated. The optimum thickness of the polymer film was obtained after ten cyclic voltammetric runs. This film has a Nernstian response slope of 29.19 mV/decade with a detection limit of 3.54 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-5</sup> M at 293 K by the simple potentiometric method. In addition, it has a sensitivity of 4 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-7</sup> AM <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> with a detection limit of 1.33 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-7</sup> M by the cyclic voltammetry method. Moreover, the sensor is specific to Hg <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> ions in the presence of other ions, such as Na <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">+</sup> , K <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">+</sup> , Mg <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> , Ca <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> , Co <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> , Ni <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> , Zn <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> , and Pb <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> . Furthermore, the most stable response of the sensor to Hg <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> ions in the solution of pH ranged from 4 to 6.4 for a lifetime of about eleven weeks. Moreover, the sensor was applied for detection of four natural samples: tap water; underground water; first distillate water; and another sample wasted with Hg <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> ions.

References

YearCitations

Page 1