Analytical Chemistry · 2016 · 38 citations · 18 references
Life SciencesBioengineeringImmunologyAntibody EngineeringDrug DeliveryImmunotechnologyAntigen Detection AssaysEnzyme-linked Immunosorbent AssayImmunoassay AnalysisImmunoassay DevelopmentMalariaAssayCapture AntibodiesHigh-sensitivity AssaysLocalized Surface Plasmon ResonanceMalaria Rapid Diagnostic TestsProtein DetectionSandwich Immunoassay DesignSandwich Immunoassay Development
Conventional lateral flow tests (LFTs), the current standard bioassay format used in low-resource point-of-care (POC) settings, have limitations that have held back their application in the testing of low concentration analytes requiring high sensitivity and low limits of detection. LFTs use a premix format for a rapid one-step delivery of premixed sample and labeled antibody to the detection region. We have compared the signal characteristics of two types of reagent delivery formats in a model system of a sandwich immunoassay for malarial protein detection. The premix format produced a uniform binding profile within the detection region. In contrast, decoupling the delivery of sample and labeled antibody to the detection region in a sequential format produced a nonuniform binding profile in which the majority of the signal was localized to the upstream edge of the detection region. The assay response was characterized in both the sequential and premix formats. The sequential format had a 4- to 10-fold lower limit of detection than the premix format, depending on assay conjugate concentration. A mathematical model of the assay quantitatively reproduced the experimental binding profiles for a set of rate constants that were consistent with surface plasmon resonance measurements and absorbance measurements of the experimental multivalent malaria system.
18
Limit of blank, limit of detection and limit of quantitation.
David Armbruster, Terry Pry · PubMed · 2008 · 2.1K citations · Full text
Transport in two-dimensional paper networks
Elain Fu, Stephen A. Ramsey, Peter Kauffman et al. · Microfluidics and Nanofluidics · 2010 · 308 citations · Full text
Elain Fu, Tinny Liang, Paolo Spicar-Mihalic et al. · Analytical Chemistry · 2012 · 273 citations
Development of Rapid One-Step Immunochromatographic Assay
Se‐Hwan Paek, Seung Hwa Lee, Joung‐Hwan Cho et al. · Methods · 2000 · 221 citations
Enhanced Sensitivity of Lateral Flow Tests Using a Two-Dimensional Paper Network Format
Elain Fu, Tinny Liang, Jared Houghtaling et al. · Analytical Chemistry · 2011 · 217 citations · Full text