We describe an improved method for continuous collection of bile from unrestrained rats. Use of an externally accessible, continuous-loop cannula when cannulating the common bile duct allows for full recovery from anesthetic effects and maintenance of a normal bile salt pool until the cannula loop is cut. Bile resulting from the cut cannula is diverted into a surgically implanted glass collection vessel and removed periodically via an externalized sampling port. Bile flow over a 24-hour collection period averaged 0.98 +/- 0.04 ml/hr (Mean +/- SEM, n = 9) with no gross pathological changes noted upon necropsy. This technique offers the capability of reestablishing conditions as close to physiologic as possible postsurgery to minimize potential artifacts during bile collection.