Optics Letters · 2015 · 72 citations · 6 references
EngineeringBioengineeringBiomedical EngineeringBiomedical ImagingBiophotonicsOpticsLight-tissue InteractionOptical CoherenceOptical Coherence TomographyOptical ImagingRetinal ImagingVascular ImagingBiomechanical TestingDirect MeasurementFrequency-dependent PropagationMotion SensitivityOptical Pulse PropagationPhase-sensitive Optical Coherence TomographyPulse PropagationPulse Wave Propagation
We demonstrate a new noninvasive method to assess biomechanical properties of the retinal vascular system. Phase-sensitive full-field swept-source optical coherence tomography (PhS-FF-SS-OCT) is used to investigate retinal vascular dynamics at unprecedented temporal resolution. The motion of retinal tissue that is induced by expansion of the vessels therein is measured with an accuracy of about 10 nm. The pulse shapes of arterial and venous pulsations, their temporal delays, as well as the frequency-dependent pulse propagation through the capillary bed, are determined. For the first time, imaging speed and motion sensitivity are sufficient for a direct measurement of pulse waves propagating with more than 600 mm/s in retinal vessels of a healthy young subject.
6
Photoacoustic microscopy of blood pulse wave
Cheng‐Hung Yeh, Song Hu, Konstantin Maslov et al. · Journal of Biomedical Optics · 2012 · 40 citations · Full text
Pulse wave velocity in retinal arteries of healthy volunteers
Konstantin Kotliar, Marcus Baumann, Walthard Vilser et al. · British Journal of Ophthalmology · 2010 · 38 citations · Full text