Tumori Journal · 2007 · 18 citations · 31 references
MedicineOncologyRadiation OncologyRadiation DosimetryRadiation ProtectionRadiation ShieldingExternal Beam RadiotherapyMedical Radiation ShieldingPhantom DosimetryRadiation Dose MeasurementRadiation TherapyRadiation Treatment PlanningDosimetersExternal Beam Radiotherapy DosimetryExternal Beam Radiotherapy Phantom DosimetryFetal Exposure AssessmentFetal Radiation ExposureRadiation Dose AssessmentRadiation Dose EstimationThermoluminescent Dosimeters
AIMS AND BACKGROUND: In vivo and phantom dosimetry is reported to estimate the fetal dose and evaluate the effectiveness of a special shielding device to reduce fetal exposure in a woman undergoing postoperative radiation therapy for synovial oral cavity sarcoma at the 30th week of pregnancy. METHODS: In vivo measurements were performed by placing thermoluminescent dosimeters on 3 points for fetal dose estimation: uterine fundus, umbilicus and pubis. A Rando anthropomorphic phantom was used to simulate radiotherapy. We also performed off-axis dose measurements for wedged beams to estimate the dose contribution of this accessory used in the treatment. RESULTS: The special shielding device reduced the fetal dose by 70% on average, despite the presence of wedges, which increased the dose by a factor of about 2.5. Before delivery the patient received 48 Gy, and from the in vivo measurements a fetal dose of 8.5, 1.7 and 0.7 cGy was estimated to the uterine fundus, umbilicus and pubis, respectively. CONCLUSIONS: Pre-treatment simulation in the same irradiation conditions is the only reliable approach to predict the fetal dose. By using a special shielding device, radiotherapy can be optimized while keeping the fetal exposure below the risk of deterministic damage.
31
ICRU Report 50—Prescribing, Recording and Reporting Photon Beam Therapy
Douglas Jones · Medical Physics · 1994 · 601 citations
Coexistence of Pregnancy and Malignancy
Nicholas Pavlidis · The Oncologist · 2002 · 521 citations · Full text
Medicine, Obstetrics, Oncology +17