Radiology · 2016 · 201 citations · 9 references
MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyRadiation DetectionAbdominal ImagingAbdominal RadiologyComputed TomographyMedical ImagingRadiation Imaging DetectorsRadiographic ImagingEnergy-integrating DetectorsHounsfield Unit MeasurementHounsfield UnitsInstitutional Review Board ApprovalPhoton Counting ImagingPhoton-counting Computed TomographyRadiation Dose AssessmentRadiographic Image Quality
PURPOSE: To evaluate the performance of a prototype photon-counting detector (PCD) computed tomography (CT) system for abdominal CT in humans and to compare the results with a conventional energy-integrating detector (EID). MATERIALS AND METHODS: The study was HIPAA-compliant and institutional review board-approved with informed consent. Fifteen asymptomatic volunteers (seven men; mean age, 58.2 years ± 9.8 [standard deviation]) were prospectively enrolled between September 2 and November 13, 2015. Radiation dose-matched delayed contrast agent-enhanced spiral and axial abdominal EID and PCD scans were acquired. Spiral images were scored for image quality (Wilcoxon signed-rank test) in five regions of interest by three radiologists blinded to the detector system, and the axial scans were used to assess Hounsfield unit accuracy in seven regions of interest (paired t test). Intraclass correlation coefficient (ICC) was used to assess reproducibility. PCD images were also used to calculate iodine concentration maps. Spatial resolution, noise-power spectrum, and Hounsfield unit accuracy of the systems were estimated by using a CT phantom. RESULTS: In both systems, scores were similar for image quality (median score, 4; P = .19), noise (median score, 3; P = .30), and artifact (median score, 1; P = .17), with good interrater agreement (image quality, noise, and artifact ICC: 0.84, 0.88, and 0.74, respectively). Hounsfield unit values, spatial resolution, and noise-power spectrum were also similar with the exception of mean Hounsfield unit value in the spinal canal, which was lower in the PCD than the EID images because of beam hardening (20 HU vs 36.5 HU; P < .001). Contrast-to-noise ratio of enhanced kidney tissue was improved with PCD iodine mapping compared with EID (5.2 ± 1.3 vs 4.0 ± 1.3; P < .001). CONCLUSION: The performance of PCD showed no statistically significant difference compared with EID when the abdomen was evaluated in a conventional scan mode. PCD provides spectral information, which may be used for material decomposition.
9
Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging
Jan S. Iwanczyk, E. Nygärd, Meirav Oded et al. · IEEE Transactions on Nuclear Science · 2009 · 293 citations · Full text
Saul N. Friedman, George S. K. Fung, Jeffrey H. Siewerdsen et al. · Medical Physics · 2013 · 199 citations
Material separation in x‐ray CT with energy resolved photon‐counting detectors
Xiaolan Wang, Dirk Meier, Katsuyuki Taguchi et al. · Medical Physics · 2011 · 198 citations