Journal of The Electrochemical Society · 1980 · 85 citations · 0 references
Natural SciencesMaterials EngineeringMaterials ScienceCorrosion ScienceElectrochemistryMetallic MaterialsCorrosion EngineeringCorrosion KineticsCorrosion MechanismsCorrosion-resistant MaterialsElectrochemical CorrosionCathodic PolarizationCorrosion Of Copper AlloysCorrosion ProcessesElectrochemical Corrosion ProcessesMetal DissolutionOxygen Reduction ReactionOxygen Reduction Reaction KineticsPolarization Curves
The mechanism of formation of the protective layer on commercial Cu‐9.4Ni‐1.7Fe alloy in aerated 3.4 weight percent solution at room temperature was investigated for various times up to 191 days. The weight of the sample, the weight of the corrosion product layer, and the anodic and cathodic polarization curves were measured before and after the corrosion periods. Results of these experiments show that the decrease in the overall corrosion rate by formation of the protective layer is due mainly to a decrease in the oxygen reduction rate and only slightly to a decrease in the metal dissolution rate. They indicate that to a large degree, if not entirely, the location of the oxygen reduction reaction is the surface of a thin, strongly adherent inner layer which is in contact with electrolyte as a result of the porous nature of the much thicker outer layer. The rate‐determining step of this reaction was found to be the transport of electrons through the inner layer, which increases in thickness according to the parabolic law. The results futher show that the (modest) decrease in the anodic reaction during open‐circuit corrosion is due entirely to the porous outer layer.