Veterinary MedicineBiomedical EngineeringRadiologyDiagnostic ImagingUltrasonographyUltrasoundDiagnostic Imaging SystemsDiagnostic UltrasonographyGastrointestinal ImagingImage Quality AssessmentMedical ImagingUltrasound ImagingB-mode ImagingPancreatic Cystic LesionsPancreatic Cystic NeoplasmsPancreatic Disease ImagingPancreatic UltrasonographyPancreatic UltrasoundSolid LesionsTissue Harmonic Imaging
BACKGROUND AND STUDY AIMS: Recently, tissue harmonic echo (THE) imaging has advanced with the development of a new endoscopic ultrasound (EUS) monitor/processing unit. With this new technology, penetration (THE-P) and resolution (THE-R) images can be obtained. The aim of this study was to investigate the performance of this novel THE imaging using a new processing unit for pancreatic diseases. PATIENTS AND METHODS: Fifty patients with pancreatic lesions (38 cystic, 12 solid) were retrospectively analyzed. At each examination, 3 EUS images of the same pancreatic lesion were obtained using B-mode, THE-P mode, and THE-R mode imaging. Each set of EUS images was randomly arranged and evaluated independently by 4 physicians blinded to the imaging technique. Images were compared using a Likert scale 5-point grading system for each parameter. RESULTS: For cystic lesions, THE-P mode images were significantly superior to conventional B-mode images for visualizing the boundary, septum, nodules, and total image quality (P < 0.05). THE-R mode images were significantly superior to conventional B-mode images for visualizing the boundary, septum, and total image quality (P < 0.05). However, for solid lesions, there was no significant difference in all the evaluation points between THE-P and conventional B-mode images. THE-R mode images were inferior to conventional B-mode images for visualizing the boundary, internal structure, and total image quality (P < 0.05). CONCLUSIONS: For pancreatic cystic lesions, THE mode images provided better lesion characterization than conventional B-mode images. Further research is required to determine if this improvement will result in improved EUS diagnostics.
10
Clinical use of ultrasound tissue harmonic imaging
F. Tranquart, N. Grenier, Véronique Eder et al. · Ultrasound in Medicine & Biology · 1999 · 453 citations
EUS, PET, and CT scanning for evaluation of pancreatic adenocarcinoma
Howard R. Mertz, Panos Sechopoulos, Dominique Delbeke et al. · Gastrointestinal Endoscopy · 2000 · 324 citations
Hideki Ishikawa, Yoshiki Hirooka, Akihiro Ito et al. · Gastrointestinal Endoscopy · 2003 · 55 citations