Clean air and environmental quality · 1997 · 18 citations · 0 references
Public HealthBuilding ScienceEnvironmental SciencesAir PollutionEnvironmental HealthIndoor Environmental QualityAir PollutantsAir Pollution MeasurementAir QualityExposure AssessmentIndoor Air PollutionIndoor Environmental ConditionsFormaldehydeFormaldehyde ExposureIndoor Air ContaminantsIndoor Air PollutantsIndoor Air QualityIndoor Air TemperatureParticleboardPassive Sampling
Indoor exposure to formaldehyde has been associated with respiratory symptoms in children. Formaldehyde was therefore monitored as part of a larger indoor environmental study in the Latrobe Valley, Victoria, Australia. Passive samplers were used to measure levels inside and outside 80 houses on four occasions over one year. Only three samples exceeded the guideline of 100 ppb, and the median level was 12.6 ppb, with a maximum of 109 ppb indoors. Outdoor levels were very low with a median of 0.6 ppb. Presence of fibreboard, particleboard flooring, a high indoor temperature, and houses <10 years old were associated with higher formaldehyde levels. An un-vented gas heater was associated with the highest recorded levels. In addition, an estimate of total formaldehyde emitting area in each sampled room was associated with levels, but a reliable prediction of indoor formaldehyde levels was not possible by available data.