Space Science Reviews · 2015 · 310 citations · 36 references
Natural SciencesEarth SciencesGeophysicsInstrumentationNuclear InstrumentationPlasma PhysicsDetector SystemsIonospheric ElectrodynamicsPlanetary InstrumentationSolar Wind Pickup IonsTime ResolutionTime-of-flight Mass Spectrometry
The MAVEN STATIC instrument is designed to measure the ion composition and distribution functions of the cold Martian ionosphere, its heated suprathermal tail, and pickup ions accelerated by solar wind electric fields. It operates from 0.1 eV to 30 keV with 4‑second resolution, using a toroidal top‑hat electrostatic analyzer (360° × 90° field of view) coupled to a time‑of‑flight velocity analyzer that employs a –15 kV acceleration and ultra‑thin carbon foils to resolve H⁺, He²⁺, He⁺, O⁺, O₂⁺, and CO₂⁺, with microchannel plate detectors and attenuators extending the dynamic range by a factor of 10³. Early cruise‑phase measurements validate the instrument’s performance and produce initial data products.
The MAVEN SupraThermal And Thermal Ion Compostion (STATIC) instrument is designed to measure the ion composition and distribution function of the cold Martian ionosphere, the heated suprathermal tail of this plasma in the upper ionosphere, and the pickup ions accelerated by solar wind electric fields. STATIC operates over an energy range of 0.1 eV up to 30 keV, with a base time resolution of 4 seconds. The instrument consists of a toroidal "top hat" electrostatic analyzer with a $360^{\circ} \times 90^{\circ}$ field-of-view, combined with a time-of-flight (TOF) velocity analyzer with $22.5^{\circ}$ resolution in the detection plane. The TOF combines a $-15~\mbox{kV}$ acceleration voltage with ultra-thin carbon foils to resolve $\mathrm{H}^{+}$ , $\mathrm{He}^{++}$ , $\mathrm{He}^{+}$ , $\mathrm{O}^{+}$ , $\mathrm{O}_{2}^{+}$ , and $\mathrm{CO}_{2}^{+}$ ions. Secondary electrons from carbon foils are detected by microchannel plate detectors and binned into a variety of data products with varying energy, mass, angle, and time resolution. To prevent detector saturation when measuring cold ram ions at periapsis ( $\sim10^{1 1}\mbox{eV/cm}^{2}\,\mbox{s}\,\mbox{sr}\,\mbox{eV}$ ), while maintaining adequate sensitivity to resolve tenuous pickup ions at apoapsis ( $\sim10^{3}~\mbox{eV/cm}^{2}\,\mbox{s}\,\mbox{sr}\,\mbox{eV}$ ), the sensor includes both mechanical and electrostatic attenuators that increase the dynamic range by a factor of $10^{3}$ . This paper describes the instrument hardware, including several innovative improvements over previous TOF sensors, the ground calibrations of the sensor, the data products generated by the experiment, and some early measurements during cruise phase to Mars.
36
The THEMIS ESA Plasma Instrument and In-flight Calibration
J. P. McFadden, C. W. Carlson, D. E. Larson et al. · Space Science Reviews · 2008 · 1.1K citations
The Mars Atmosphere and Volatile Evolution (MAVEN) Mission
B. M. Jakosky, R. P. Lin, J. M. Grebowsky et al. · Space Science Reviews · 2015 · 813 citations · Full text
The MAVEN Magnetic Field Investigation
J. E. P. Connerney, J. R. Espley, P. Lawton et al. · Space Science Reviews · 2015 · 543 citations · Full text
Natural Sciences, Electrical Engineering, Electromagnetism +16
Cassini Plasma Spectrometer Investigation
D. T. Young, J. J. Berthelier, Michel Blanc et al. · Space Science Reviews · 2004 · 514 citations