Measurement Science and Technology · 2015 · 169 citations · 162 references
Natural SciencesElectrical EngineeringPhysicsActuatorsFluid DynamicsPlasma PhysicsActuator DiagnosticsHigh-temperature PlasmasPlasma DiagnosticsPlasma FundamentalsPlasma HeatingPlasma SourcesAtmospheric-pressure PlasmasCorona DischargesDielectric Barrier DischargesDirect Current DischargesElectrothermal ActuatorsFlow Control DevicesFlow Velocity MeasurementsVelocity
The popularity of plasma actuators as flow control devices has sparked a flurry of diagnostic efforts towards their characterisation. This review article presents an overview of experimental investigations employing diagnostic techniques specifically aimed at AC dielectric barrier discharge, DC corona and nanosecond pulse plasma actuators. Mechanical, thermal and electrical characterisation techniques are treated. Various techniques for the measurement of induced velocity, body force, heating effects, voltage, current, power and discharge morphology are presented and common issues and challenges are described. The final part of this report addresses the effect of ambient conditions on the performance of plasma actuators.
162
Digital particle image velocimetry
Christian Willert, M. Gharib · Experiments in Fluids · 1991 · 2K citations
Airflow control by non-thermal plasma actuators
Éric Moreau · Journal of Physics D Applied Physics · 2007 · 1.6K citations