American Journal of Veterinary Research · 1992 · 24 citations · 0 references
Veterinary MedicineOrthopaedic SurgeryOrthopedic SurgeryEquine SurgeryOrthopedicsSmall Animal OrthopedicsJoint ProtectionSplint CareDeformationDeformation MeasurementFascial BiomechanicsFiberglass CastsLigament StrainLigament Stress-strain BehaviorSesamoid LigamentsTemperature Compensation
Summary Liquid mercury strain gauges were implanted in the forelimb proximal sesamoidean ligaments ( psl ) of 8 adult horses. The gauges measured psl strain while horses were standing with or without external support. In 6 of the horses, the gauges also measured PSL strain in horses at a walk, with or without external support. Gauges were enclosed within sliding polypropylene tubes to prevent nonaxial deformation. Each gauge was placed in 1 arm of a low-resistance half-bridge circuit. To provide temperature compensation, a dummy gauge was placed in the adjacent arm of the bridge circuit and was implanted next to the active gauge in the surrounding fascial tissue. External support included fiberglass cast support ( cast ), dorsal fetlock splint support ( dfs ), support wraps of 3 bandage materials (SW1, SW2, and SW3), and support wrap with caudal splint (SW4). The cast was applied, with the fetlock and foot in weightbearing position, from the proximal portion of the metacarpus distal to and including the foot. The dfs was applied by placing the cranial half of the fiberglass cast on the dorsal aspect of the instrumented limb. The SW1, SW2, and SW3 were applied in a figure-8 pattern around the fetlock, using 50% of the linear stretch capacity of the bandage material, with the horse standing squarely on all 4 limbs. The SW4 was applied identically to the other support wraps, with the exception of addition of a flexible caudal splint incorporated in the support wrap. Mean maximal strain while standing (∈s) without external support for 8 horses was 6.0% (range, 3.8 to 7.5%). Mean maximal strain at a walk (∈s) without external support for 6 horses was 5.9% (range, 4.1 to 8.2%). Only cast and dfs significantly reduced ∈s. Cast support reduced ∈s to a mean ± SEM 1.4 ± 0.2%, 77% reduction in total strain ( P <0.0001). Use of dfs reduced ∈s to a mean 4.2 ± 0.3%, 30% reduction in total strain ( P < 0.0001). The SW1, SW2, and SW3 did not significantly reduce ∈s (power > 0.8, δ = 20%). Conclusions cannot be made for reduction of ∈s with SW4 (power < 0.8, δ = 20%) because of low sample size. Only cast and dfs significantly reduced ∈w. Cast support reduced ∈w to a mean 2.0 ± 0.3%, 67% reduction in total strain ( P < 0.0001). The dfs reduced ∈w to a mean 4.4 ± 0.4%, 25% reduction in total strain ( P < 0.008). The SW1, SW2, and SW3 did not significantly reduce ∈w (power > 0.8, ∂ = 20%). Conclusions cannot be made for reduction of ∈w with SW4 (power < 0.8, ∂ = 20%) because of low sample size.