Journal of Applied Physiology · 1983 · 33 citations · 0 references
Health ProfessionsPhysiologyExercise TestingPulmonary Function TestingVentilationAirway ResistanceMechanical VentilationPositive End-expiratory PressurePulmonary MechanicsPulmonary PhysiologyRespiratory PhysiologyAir Breathing AdaptationsBreathing MechanicsLung ComplianceMinute Ventilation ResponseMouth Pressure MeasurementRespiratory ResponseRespiratory System ResistanceWork Of Breathing
To characterize the ventilatory response to resistive unloading, we studied the effect of breathing 79.1% helium-20.9% oxygen (He-O2) on ventilation and on mouth pressure measured during the first 100 ms of an occluded inspiration (P100) in normal subjects at rest. The breathing circuit was designed so that external resistive loads during both He-O2 and air breathing were similar. Lung resistance, measured in three subjects with an esophageal balloon technique, was reduced by 23 +/- 8% when breathing He-O2. Minute ventilation, tidal volume, respiratory frequency, end-tidal partial pressure of CO2, inspiratory and expiratory durations, and mean inspiratory flow were not significantly different when air was replaced by He-O2. P100, however, was significantly less during He-O2 breathing. We conclude that internal resistive unloading by He-O2 breathing reduces the neuromuscular output required to maintain constant ventilation. Unlike studies involving inhaled bronchodilators, this technique affords a method by which unloading can be examined independent of changes in airway tone.