Concepedia

Publication | Closed Access

Fatigue behavior of the resin-resin bond of partially replaced resin-based composite restorations.

65

Citations

0

References

2003

Year

Abstract

Initial repair bond strengths were significantly higher for the groups with additional application of flowable composite compared to composite only (P<0.05; Mann Whitney U test). Diamond finishing revealed the lowest bond strengths. Fatigue bond strengths exhibited the worst results for Group 1 as well, but were similar for Groups 2-5. In the Class II partial repair simulation, Groups 3 and 5 with additional flowable lining exhibited significantly better marginal quality and significantly lower leakage, whereas the other groups revealed up to 100% separation between aged and freshly applied composite.