Nuklearmedizin - NuclearMedicine · 2001 · 48 citations · 26 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyPulmonologyPulmonary EmbolismPulmonary Embolism ImagingPulmonary ImagingPulmonary Nuclear ImagingThromboembolic DiseaseThrombosisLung Perfusion ImagingLung Perfusion ScansMatched Control GroupRetrospective Case StudyTransverse VentilationVenous Thromboembolism AssessmentVenous Thromboembolism DiagnosisVentilation-perfusion Scintigraphy
PURPOSE: Conventional planar ventilation/perfusion (V/P)-imaging in those patients suspected of suffering from pulmonary thromboembolism (PTE) is of limited diagnostic value. It is the purpose of this retrospective study to determine whether the use of V/P-SPECT using Technegas might reduce the rate of those diagnostic uncertainties and might lead to better results. METHODS: 991 patients (660 female, 331 male, age 18-90, mean 60), referred to our laboratory with suspected PTE, were examined as follows: patients inhaled 37 MBq of Technegas in the supine position and a SPECT-acquisition was started. Following SPECT-completion, 185 MBq 99mTc-MAA was injected intravenously. SPECT was then repeated. Coronal and transverse ventilation and perfusion SPECT-slices were reconstructed and compared section by section. 85 patients underwent control scans by the same technique at a mean interval of 22 months after the original scans. RESULTS: As the SPECT images in almost all cases made a clear match/mismatch decision possible, we categorized all patients as embolic (PTE+) if there was at least one mismatching defect, and as non embolic (PTE-) if there were none. Our results were: PTE+: 178 patients (18%), PTE-: 808 patients (81%), uncertain: 5 patients (0.5%), if 34 triple-match defects are included: 39 patients (3.9%). 46 patients, categorized as PTE+ underwent a control V/P scan after anticoagulant therapy. In 44 of these patients, PTE was confirmed by the controls. In a control group of 39 PTE- patients, control scans were unchanged in 38 cases. From these observations we can calculate a sensitivity of 96% and a specificity of 97%. CONCLUSION: We conclude that V/P imaging can be improved significantly by V/P SPECT using Technegas.
26
Value of the Ventilation/Perfusion Scan in Acute Pulmonary Embolism
JAMA · 1990 · 2.7K citations
Regional distribution of ventilation and perfusion as a function of body position.
Katsumi Kaneko, J Milic-Emili, Myrna Dolovich et al. · Journal of Applied Physiology · 1966 · 454 citations
Medicine, Anatomy, Physiology +13
Pulmonary embolism: prospective comparison of spiral CT with ventilation-perfusion scintigraphy.
John R. Mayo, Martine Rémy‐Jardin, N L Müller et al. · Radiology · 1997 · 400 citations