Journal of Applied Physiology · 1979 · 31 citations · 0 references
MedicineKinesiologyPhysiologyExercise PhysiologyExercise TestingPulmonologyAerobic ExerciseAerobic FitnessCardiopulmonary Exercise TestingCardiorespiratory FitnessNasal ObstructionNasal PhysiologyAirflow ResistanceHeart RateNasal Airflow DynamicsNasal Airflow MeasurementNasal Airflow ResistanceNasal Airway ResistanceNasal Resistance MeasurementRespiratory Mechanics During Exercise
Nasal mucous velocity and nasal airflow resistance were measured in nine healthy subjects before, during 5 min, and 1 h after submaximal exercise of 20 min with a cycle ergometer set in such a way that heart rate ranged from 125 to 135 beats/min. Nasal mucous velocity rose from a base line of 7.6-12.7 mm/min during exercise and returned to the base-line value 5 and 60 min after exercise. The mean expiratory nasal airflow resistance at a flow of 0.4 l/s decreased from a base line of 1.6-0.6 cmH2O . (l/s)-1 during exercise and returned to the baseline value 5 and 60 min after exercise.