Radiation Oncology · 2015 · 137 citations · 26 references
MedicineOncologyRadiation OncologyClinical Decision SupportRadiation ProtectionTreatment PlanningCancer Treatment PlanningPersonalized Treatment PlanningPlan OptimizationPlan Quality AssuranceRadiation TherapyRadiation Treatment PlanningAutomated Plan Quality AssuranceAutomated Treatment PlanningPersonalized Radiotherapy PlanningPlan Quality AssessmentRadiotherapy Dose PlanningRadiotherapy Plan EvaluationTreatment Plan EvaluationTreatment Planning Dosimetry
BACKGROUND: Treatment plan quality assurance (QA) is important for clinical studies and for institutions aiming to generate near-optimal individualized treatment plans. However, determining how good a given plan is for that particular patient (individualized patient/plan QA, in contrast to running through a checklist of generic QA parameters applied to all patients) is difficult, time consuming and operator-dependent. We therefore evaluated the potential of RapidPlan, a commercial knowledge-based planning solution, to automate this process, by predicting achievable OAR doses for individual patients based on a model library consisting of historical plans with a range of organ-at-risk (OAR) to planning target volume (PTV) geometries and dosimetries. METHODS: A 90-plan RapidPlan model, generated using previously created automatic interactively optimized (AIO) plans, was used to predict achievable OAR dose-volume histograms (DVHs) for the parotid glands, submandibular glands, individual swallowing muscles and oral cavities of 20 head and neck cancer (HNC) patients using a volumetric modulated (RapidArc) simultaneous integrated boost technique. Predicted mean OAR doses were compared with mean doses achieved when RapidPlan was used to make a new plan. Differences between the achieved and predicted DVH-lines were analyzed. Finally, RapidPlan predictions were used to evaluate achieved OAR sparing of AIO and manual interactively optimized plans. RESULTS: For all OARs, strong linear correlations (R(2) = 0.94-0.99) were found between predicted and achieved mean doses. RapidPlan generally overestimated the amount of achievable sparing for OARs with a large degree of OAR-PTV overlap. RapidPlan QA using predicted doses alone identified that for 50 % (10/20) of the manually optimized plans, sparing of the composite salivary glands, oral cavity or composite swallowing muscles could be improved by at least 3 Gy, 5 Gy or 7 Gy, respectively, while this was the case for 20 % (4/20) AIO plans. These predicted gains were validated by replanning the identified patients using RapidPlan. CONCLUSIONS: Strong correlations between predicted and achieved mean doses indicate that RapidPlan could accurately predict achievable mean doses. This shows the feasibility of using RapidPlan DVH prediction alone for automated individualized head and neck plan QA. This has applications in individual centers and clinical trials.
26
Predicting dose‐volume histograms for organs‐at‐risk in IMRT planning
L. Appenzoller, Jeff M. Michalski, Wade L. Thorstad et al. · Medical Physics · 2012 · 383 citations
A planning quality evaluation tool for prostate adaptive IMRT based on machine learning
Xiaofeng Zhu, Yaorong Ge, Taoran Li et al. · Medical Physics · 2011 · 323 citations · Full text