Modeling of Aqueous Urea Solution Injection with Characterization of Spray-wall Cooling Effect and Risk of Onset of Wall Wetting

Lorenzo Nocivelli, Gianluca Montenegro, Yujun Liao, Panayotis Dimopoulos Eggenschwiler, John Campbell, Nicola Rapetto

Energy Procedia · 2015 · 14 citations · 8 references

DOIFull text

Open access

Concepts

Abstract

The definition of a sufficiently resolved heat transfer model with spray cooling effect as a function of each droplet kinetic and thermal parameters is a key factor in the numerical simulation of aqueous urea (AUS) based Selective Catalytic Reduction (SCR) exhaust after-treatment systems. A consolidated spray-wall interaction model [1] has been implemented on the open source 3D finite volume software OpenFOAM and a critical investigation of its behaviour in engine representative conditions is reported. A simplified test case is used to highlight the influence of the chosen model on the numerical simulation of the system, reducing the importance of the other spray sub-models in the Lagrangian-Eulerian computational framework. The coupling between the droplet evaporation heat flux and the gas-solid interface thermal boundary condition has been studied, pointing out the significance of each contribution. The main focus of this work is to present reference conditions to simulate the spray-dry wall spray impingement behavior to determine the ‘onset of wall wetting’ thermal conditions.

References

8