1961 · 10 citations · 0 references
Natural SciencesMaterials EngineeringMaterials ScienceCorrosion ScienceInorganic ChemistryMaterials ChemistryCorrosion EvaluationCorrosion InspectionCorrosion MechanismsCorrosion MonitoringCorrosion TestingCorrosion-resistant MaterialsCorrosion AssessmentCorrosion DiagnosticsInterim Reports
The zirconium fluoride-base fluoride mixture NaFZrF/sub 4/-UF/sub 4/ (50- 46-4 mole%), referred to as "fluoride 30," was circulated in Inconel thermal convection loops for periods varying from 500 to 5000 hr and at a hot-leg temperature of 1500 deg F. The purpose of this program was to develop an understanding of the corrosion mechanism accompanying the circulation of zirconium fluoride-base mixtures in Inconel. The attack in the Inconel loops was in the form of subsurface voids formed by selective leaching of chromium from the alloy. After 500 hr of operation, the voids were found to depths of about 10 mils, with the depth continuing to increase at a rate of about 4 mils per 1000 hr of operation. The effects of such variables as time, hot-leg temperature, temperature drop, fluoride purity, loop size and shape, and inhibitors on the depth of corrosion were studied. It was found that the attack was reduced when a portion of the uranium was present in the trivalent state, but the results were not reproducible. A few tests also were carried out in loops constructed from nickel, stainless steels, iron, Hastelloy B, molybdenum, and niobium. A limited amount of work was done on Inconel loops circulating alkali metal-base mixtures (NaF, LiF, KF. UF/sub 4/) with portions of the uranium in the trivalent state. Reduced attacks were found, but disproportionation and production problems require additional study. (auth)